Blinking red light is the most common phenomenon among them. Just follow the below steps to reset it: No, a gas control valve cant be fixed. Also, check the connectors for physical damage. But when the thermopile voltage becomes low, the pilot light goes, and the gas valve shuts down and turns off the gas supply. The faulty ignition control module is another major reason for the Rheem gas water heaters failed ignition lockout. Eitherthe fuse has blown, or a circuit breaker is tripped. It is considered one of the big problems in Rheem water heater. This is a problem that Rheem is aware of, and they consider the hot water heater to be functioning perfectly fine. It should not be loosened and fully seated. To test the thermocouple electrically, you should use a multimeter. Finally, reassemble the burner assembly and turn on the water heater. If there is no issue with the thermopile and the pilot light goes out, I bet the gas valve is the culprit. Rheem Water Heater Gas Valve SP20164 Brand: RHEEM MFG SALES, INC 4 ratings $11370 Rheem/Richmond Water Heater Natural Gas Valve SP8555B RHEEM MFG SALES, INC See more product details Consider this Amazon's Choice product that delivers quickly Amazon's Choice Picture 1 of 8. Just move to the temperature control knob and set your desired temperature. In this article, Ill discuss the common causes of Rheem gas control or valve failure with 7 flashes. But still, if the issue remains, it is sure the control board gets defective. If the igniter does not get the voltage needed, you need to replace the defective igniter. Free shipping. For this, disconnect the thermopile by wriggling it a bit. Free shipping for many products! Sold by enriceshop and ships from Amazon Fulfillment. Remove the front access cover and disconnect all the attachments with the gas control valve. Report this item - opens in new window or tab. Honeywell WV4460E2022 Water Heater Natural Gas Control Valve Rheem. When I moved into my house about 9 months ago, we had to have a plumber come fix a leaky valve on the hot water heater. And why cant the problem be accessed before sending the gas valve. Otherwise, when the thermocouple senses the flame, it keeps the gas valve open to supply gas to the pilot light. 3.5 3.5 out of 5 stars (15) $116.95 $ 116. Testing for continuity with a multimeter is an excellent way to confirm if the thermocouple is broken. To solve this major problem, we have discussed the 9 reasons and the corresponding effective solutions. Electric water heater If you're getting some hot water, and you can hear the unit heating, check the thermostat set point. Call 1-855-400-2552 before noon for same-day . You have to follow the above troubleshooting steps to erase the error from your water heater. But, it will be okay if you have proper knowledge of the possible signs and presentations to enable you to carry out simple fixes when needed. First, check the thermopile connection to see if it isproperly connected to the gas control valve. Use 400-grit sandpaper to clean the surface of the sensor. While you can try to increase the water temperature to kill the bacteria, cleaning up your heater with a good cleanser like bleach would be best. Due to damaged wiring connections, the burner doesnt get the electric power that is needed to ignite the heater. So far the options to 'fix' this problem are to 1) crack my attic door open to allow cold air to circulate with the hot air in the attic, 2) put a fan in the attic to keep it circulating, or 3) have attic efficiency techs come out and make my attic more efficient (and cooler) to prevent this. You will find carbon or dirt build-up on the thermocouple body. We are going through a terrible situation- first the pandemic and second, the war. Shank Length - (NG) for Sure Comfort Water Heaters. Rheem water heater is in the range of the most well-known brand in the HVAC industry for producing reliable and long-lasting. Just remove the two-wire connectors to the board. Take the resistance reading of the sensor. COPYRIGHT 2023. You must replace the gas valve if the Rheem water heater gas valve is at fault. Replace the defective thermopile, and then the 2 blinkings will erase from the heater. It will save you hundreds of bucks. Then replace the mounting screw and ensure a secured connection. san gabriel valley > Clean it first using sandpaper and scrub off all the dirt. 72. However, Rheem promises to offer full inclusion on the defective valve, and the brand is also giving $100 credits to fix organizations to replace the defective parts. Sponsored. Fortunately, we broke down the way of changing it. The recall service Rheem offers goes a long way in expressing how the brand is devoted to the satisfaction of its customers. Free shipping for many products! These valves have a documented history of failing on Rheem water heaters that were manufactured in 2020/2021. Includes an integrated NTC temperature sensor. . After that time, turn the knob ON position. I called a plumber to take a look. All Right Reserved by FIREPLACEHUBS. If you find the reading below 400, be sure the element is defective. The responsive factors for 9 times error blinking include: The common signs that define that you need a new water heater are getting rusty water out of the tap, making strange noises, not getting hot water, the heater overheating, water leakage, and many more. Accumulating sediment buildup in the sensor or damaged wiring is the root reason for temperature sensor failure. Rheem water heater red light flashing at a different number of times indicates several malfunctions from the heater element. Rheem water heaters have prorated warranty. The Rheem PROTECH Gas Control Replacement Kit contains everything that you need to replace the Gas Valve on your Rheem gas water heater. Use the adjustable wrench to detach all the lines like the thermocouple connector and other supply lines. Inconsistent gas supply to the burner leads to water temperature fluctuations and pilot light challenges. Find many great new & used options and get the best deals for Rheem Natural Gas Water Heater Burner And Gas Valve WV8840C1605 at the best online prices at eBay! Replace the bad valve. Delta SIT Gas Control Valve with 0.75 in. Commonly referred to as the "T&P" valve. After the purge duration, the blower turns off and lets the pressure switch open. how to fix Rheem water heater chamber sensor failure/9 flashes, Troubleshooting Tankless Water Heater Error Codes, Rheem Tankless Water Heater Maintenance [Why+ How To Do], Rheem Tankless Water Heater Code 61 [Why+ How To Fix], Rheem Tankless Water Heater Code 14 [Why+ How To Fix], Rheem Tankless Water Heater Code 99 [Why+ How To Fix], Rheem Tankless Water Heater Code 76 [Why+ How To Fix], Clean carbon builds up around the electrode. There are a few signs of a bad thermocouple: To deal with the defective thermocouple, follow the below methods: Note: While installing the new thermocouple, make sure it is fully seated or clicks into place. Pull the damaged igniter from the connection. "This Whirlpool Water heater was purchased through Lowe's on March 29, 2011. Just follow the steps we mentioned and make the replacement. Replace The Gas Valve 3 How To Reset Rheem Water Heater Gas Valve? Allow the thermocouple to cool down for approximately 30 minutes to 1 hour. Take a brush-attached vacuum cleanerand clean the burner chamber. There are some major connectors, including an igniter connector, burner tube, and sensor wiring connection to the gas valve. Just grab a pipe wrench, adjust its jaws, and set the pipe wrench on the gas valve. You must ensure that the newly installed flex tube attaches tightly to the control valve before turning on the gas supply for testing. I will check the warranties carefully before buying this brand again as Im on a fixed income. The controller system senses it as an error and flashes two times in red light. Generally, Rheem has excellent prestige for producing credible water heaters, making them a go-to brand for most customers. A dirty pilot tube is another common cause of a Rheem water heater red light flashing 7 times. Click to . In simple terms, a faulty Rheem water heater gas valve will impede gas flow to the pilot light, which is solely responsible for igniting the appliance for heating to occur. The gas control valve in a water heater is used to regulate the gas flow. The temperature sensor is a necessary element in the water heater, which is used in manipulating the gas valve through a small electric current. Also,place the tip of the thermocouple in the proper position. Step 2: Remove the screws of the burner assembly and slide it out carefully. Rheem gas water heater installation process from start to finish what you need to know! Take an emery cloth and clean the soot build-up. Inspect the pressure relief valve, and clean specks of dirt blocked into it. Replace the defective connector. This time, the control waits 30 minutes and attempts ignition again. We will get back to you ASAP. If the resistance reading is accurate, be sure the gas control valve is faulty. Change the fuel line if needed. Yes, there is a recall on Rheem gas water heaters whenever a particular component is faulty and exposes consumers to risks. If a leak is found, tighten all gas connections and retest them with soapy water until no leaks are detected. Replace the cracked hose. Go through the below section to get the solutions for your Rheem water heater gas valve problem. These pilot lights are small enough that when it's hot, they don't sufficiently heat the air and promote enough air circulation to keep it burning. Still, if you have any queries, feel free to ask us through comments. at the best online prices at eBay! Here, the high limit switch gets trippeddue to increasing water temperature to an unsafe level and turns the heater into high-temperature mode. Follow the below article to get a complete guide to fixing each error effectively. So, its better to test the thermocouple first before swapping the old gas valve. Therefore, it gets frustrating when your water heater develops any slight fault. It signals the gas valve whether the valve needs to release or terminate the gas supply. Rheem Water Heater 8 Flashes Then 1: What Does It Mean? Make sure to clean away any dirt or debris on the tip. Once you reach 7, you can see the status light stops flashing, which indicates you reset the gas valve successfully. Inspect the igniter and check for spark. First up, clean out the blockage of the air intake vent and exhaust vent. Free shipping. In a situation with a foul gas connection or factors hindering adequate gas flow, your burner will need more energy to heat water to the required level. Wait for about 5 minutes, and then set the control knob back to the On position. Therefore, once your gas valve is faulty, you are expected to replace it entirely. Also, suck up all the dirt and debris from the air intake screen with compressed air. Turn the Gas Supply Off 2.2 Step 2. The major reasons for causing theRheem water heater to red light flashes about 4 times include: 5 times flashing on the Rheem water heater red light tells you the temperature sensor failure. Place the flame sensor back and turn the unit on. Take a multimeter and start measuring the voltage of the sensor. But in the case of resistance changes, replace the defective chamber sensor. Collection page for Water Heater Gas Valves & Controls is loaded. 9 time blinking on the Rheem water heater red light tells you chamber sensor failure of the heater. Count 1, 2, 3, 4, 5, 6, and 7 and rotate the knob back and forth at the same time. The part is required anytime the cag control is damaged or needs replacing. Heater cycles on and off quickly; Gas company said the furnace has cracks in the firebox and heat exchanger; Furnace will not start or come on; Furnace smells bad; Furnace runs, but cannot keep the house warm; Furnace is making a banging noise; Furnace is in lockout mode; Furnace has a loud banging or explosion noise; Furnace fire; Furnace .